Hi, I have a 2 gang box, containing 3 switches that is currently used in my bathroom. 1 switch is for 3 high hats, 1 is the fan, 1 is the shower light. I’m looking to put the fan and the shower light on a timer to avoid having the kids leave these on all day/night long.

In the 2 gang box, I have 4 lines, three of them are 2 wire and one is 3 wire (3 wire controls fan and shower light). The problem is I have no idea what the other lines are, where the power is coming from etc. I attached a picture to reflect the current wiring and the proposed wiring and am looking for help to ensure I am rewiring correctly. Any help would be greatly appreciated. Thanks in advance.



Top
#719874 - 06/26/12 01:16 PM Re: Bathroom Electrical Confusion [Re: sjnacasale]
BillJeffy Offline
Don't Know Squat
Carpal Tunnel

Registered: 01/02/06
Posts: 7864
Loc: USA
.
.
Your diagram is too small to read,
but if I follow the line drawing it does appear correct.

Take the light and fan and combine them on the timer
output, power (which looks like top right pole on double switch)
goes to old existing swirch and timer 'in'.

Make sure the timer can handle the amperage (or wattage) of
both the fan and lamp.

.
_________________________
.
.
Just Common Sense......
.
.
err....I'm not a Doctor, but I'll take a LOOK ! !

Top
#719876 - 06/26/12 01:31 PM Re: Bathroom Electrical Confusion [Re: BillJeffy]
code_ceis Offline
Carpal Tunnel

Registered: 04/29/09
Posts: 5393
Loc: Seneca Nation
Bill click on the pic and it opens up.
_________________________
The world is not moved only by the mighty shoves of the heroes, but also by the aggregate of the tiny pushes of each honest worker.

-Helen Keller

Top
#719877 - 06/26/12 02:08 PM Re: Bathroom Electrical Confusion [Re: BillJeffy]
sjnacasale Offline
journeyman

Registered: 03/21/05
Posts: 67
Thanks very much Bill.

So the light and fan attach to the "line" and the power (which looks like top right pole on double switch) should attach to "load" ? FYI, the picture should once double clicked.

Top
#719880 - 06/26/12 02:51 PM Re: Bathroom Electrical Confusion [Re: sjnacasale]
BillJeffy Offline
Don't Know Squat
Carpal Tunnel

Registered: 01/02/06
Posts: 7864
Loc: USA
.
.



AHHHHHHHH, that's better! (why didn't I think to clik, oh well)


REVERSE the 'line' and 'load' connections on the timer switch

The top right of the double switch (black) is the 'line'
the left side (red and black ) are loads.

.
_________________________
.
.
Just Common Sense......
.
.
err....I'm not a Doctor, but I'll take a LOOK ! !

Top
#719881 - 06/26/12 03:06 PM Re: Bathroom Electrical Confusion [Re: BillJeffy]
sjnacasale Offline
journeyman

Registered: 03/21/05
Posts: 67
Bill, thanks very much, I'll give that a try tonight!